Welcome to
Sysmex Flow Cytometry Spain!

For ordering please make sure you are in your local shop.
If you are from Spain then please continue.
Otherwise please go to your country.

Go to my country Continue

Article successfully added.

CyFlow™ IgG2a PE

CyFlow™ IgG2a PE
Species of Origin: Mouse
Antigen: IgG2a Isotype Control
Clone: PPV-04
Regulatory Status: RUO
Application: Flow cytometry (Isotype control)
Format/Fluorochrome: PE
Laser: Blue, Green, Yellow
Field of Interest: Isotype controls
Clonality: monoclonal
Emission Maximum: 576 nm
Excitation Maximum: 496 nm, 565 nm
Isotype: IgG2a
Order number: CV070533

For Research Use Only
Not for use in diagnostic or therapeutic procedures.

Concentration 0.1 mg/ml Quantity 0.1 mg Volume 1 ml Immunogen Specifity... more
CyFlow™ IgG2a PE
Concentration0.1 mg/ml
Quantity0.1 mg
Volume1 ml
Immunogen< no data >
SpecifityThis mouse IgG2a monoclonal antibody (clone PPV-04) reacts with undefined epitope on a plant pathogen.
Background InformationThe specificity of staining by monoclonal antibodies to target antigens should be verified by establishing the amount of non-specific antibody binding. Especially at higher concentration (more than 15μ/ml) the antibody staining usually has consignable background. To this end a non-reactive immunoglobulin of the same isotype is included as a negative control for each specific monoclonal antibody used in a particular immunoassay. The monoclonal antibody PPV-04, generated against a plant pathogen, does not cross-react with other species, and hence all the background that could be observed when working with this antibody would be a result of general nonspecific interactions between an mouse IgG2a molecule and the respective sample under the particular conditions. This shall help the customer to set up the experimental conditions so that the nonspecific binding of any antibody is abolished.
UsageThe reagent is designed as an isotype control for Flow Cytometry analysis. To establish the amount of non-specific antibody binding, match the concentration of the correct isotype to the recommended working concentration of the antigen-specific antibody. If the background signal of the isotype control is too high (usually when working antibody concentrations are above 10 µg/ml of incubation mixture), change the experimental conditions to reduce the background.
Storage BufferThe reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.1% (w/v) sodium azide.
StorageAvoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
StabilityDo not use after expiration date stamped on vial label.